Reasons and treatment methods for the small ultrasonic wave fluctuation of Jiangmen ultrasonic cleaning machine

2019-10-30 1666

Ultrasonic waves have a small impact for the following reasons:

The usage time is relatively long, the transducer is aging, the function is declining, and the repair method can be appropriately increased. Ultrasonic power, but this method will increase the heat generation of the transducer and cannot fundamentally solve the problem. It is advocated to replace all transducers.

Two parts of the transducer are damaged, replace the faulty transducer with a matching transducer.

3. Drift of power supply and transducer operating points, adjust the operating points from scratch.

The planned power of the cleaning machine is small. Replace or modify the power supply and increase the number of transducers.

江门超声波清洗机

5. The working environment of the cleaning machine, such as the type of cleaning agent, cleaning temperature, depth of liquid level, etc.

6. Ultrasonic attenuation caused by other unknown circumstances, such as the placement of cleaning materials, replacement of cleaning agents, etc.

How to repair may have many aspects to check, such as local ultrasonic oscillator power supply, ultrasonic oscillator, ultrasonic transducer head, and wiring

If the ultrasonic shock is small and the transducer is normal, then there is a problem with the ultrasonic generator. You can check whether the components inside are broken down.

View from two aspects. Firstly, the transducer needs to be cleaned to determine if the ultrasonic transducer is aging, as this device has a shorter lifespan; Check if the driving power is sufficient;

If you're not professional, first check the current. If the current is small, it's easy to fix

Article source: Jiangmen Ultrasonic Cleaning Machine http://www.kpzfcsb.com/